Pharmaceutical Calorimeters

Pharmaceutical solution calorimetry is particularly useful during the development phase of a solid drug compound, as it allows researchers to perform analysis of crystalline content and verify stability. The change in the heat capacity of the bonds within a molecule can be measured by differential scanning calorimetry and allows researchers to detect points of enthalpy and characterize and map the temperature-specific behavior of a drug product.

Differential scanning calorimetry allows researchers to examine the conformational changes within a biomolecule as it is exposed to a range of temperatures, allowing for a look into the protein stability and folding properties. Pharmaceutical calorimeters allow drug developers to verify the point at which a drug might become crystallized or unstable, which is especially useful in the final development of amorphous drug compounds.

CompanyNETZSCH Premier TechnologiesNETZSCH Premier TechnologiesNETZSCH Premier TechnologiesNETZSCH Premier TechnologiesNETZSCH Premier Technologies
ItemPhoto-DSC 204 F1 Phoenix Differential PhotocalorimeterDSC 200 F3 Maia Differential Scanning CalorimeterDSC 204 F1 Phoenix Differential Scanning CalorimeterDSC 204 HP Phoenix High-pressure Differential Scanning CalorimeterDSC 404 F3 Pegasus High-Temperature Differential Scanning Calorimeter
PriceInquireInquireInquireInquireInquire
Vendor Product PageCompany Product PageCompany Product PageCompany Product PageCompany Product PageCompany Product Page
TypePhoto-DSCDSCDSCDSCDSC
SensorInquireHeat Flux SystemHeat Flux SystemInquireInquire
Temperature Range-100C to 200C-170C to 600C-180C to 700C-150C to 600C-150C to 2000C
Heating RateInquire0.001 to 100 K/min0.001 to 200 K/min0.01 to 50 K/min0.001 to 50 K/min
Cooling RateInquire0.001 to 100 K/min (Depending on Temperature)max 200 K/minInquireInquire
QuantityEAEAEAEAEA
Description

The main advantage of light-curing systems is their fast reaction time. Monomer solutions which are mostly free of solvents can be cured within only a few seconds and already at low temperatures. A combination of thermal and light curing reactions is

The DSC 200 F3 Maia®, Differential Scanning Calorimeter, combines the advantages of modern technology, high sensitivity and a robust, easy-to-operate work horse. Using liquid nitrogen, the temperature range extends from -170°C to 600°C. The main

The versatile Premium Differential Scanning Calorimeter, DSC 204 F1 Phoenix®, fascinates with its unique concept: all essential operational components are integrated into the instrument and optional add-ons can be installed anytime on site.

The

Numerous physical processes and chemical reactions are influenced by the surrounding gas pressure. In practise it is therefore often necessary to conduct DSC measurements under an increased pressure.

With the high-pressure Differential Scanning

The DSC 404 F3 Pegasus®, High-Temperature Differential Scanning Calorimeter, is part of the economical NETZSCH F3-product line, which is specially tailored to the requirements of comparative material characterization and quality control.

The

Get quoteInquireInquireInquireInquireInquire