HPLC detectors fall into two main categories: universal or selective. Universal detectors typically measure a bulk property (e.g., refractive index) by measuring a difference of a physical property between the mobile phase and mobile phase with solute while selective detectors measure a solute property (e.g., UV-Vis absorbance) by simply responding to the physical or chemical property of the solute. HPLC most commonly uses a UV-Vis absorbance detector, however, a wide range of other chromatography detectors can be used. A universal detector that complements UV-Vis absorbance detection is the Charged aerosol detector (CAD).
Refractive index detectors are commonly used in HPLC. This detector provides readings by measuring the changes in the refractive index of the eluent as it moves through the flow cell. In certain cases, it is possible to use multiple detectors, for example, LCMS normally combines UV-Vis with a mass spectrometer.
Your search for HPLC returned 31 results.
Get quotes for all products
Select up to 5 products from below to compare or request more information.
- Type: Electrochemical Detector
- Pharmaceutical Application: Inquire
- Wavelength Range: Inquire
Inquire
- Type: UV-Vis Detector
- Pharmaceutical Application: Inquire
- Wavelength Range: 200 to 840 nm
Inquire
- Type: Refractive Index (RI) Detector
- Pharmaceutical Application: Inquire
- Wavelength Range: up to 880 nm
- Type: Electrochemical Detector
- Pharmaceutical Application: Inquire
- Wavelength Range: Inquire
- Type: ELSD Detector
- Pharmaceutical Application: Inquire
- Wavelength Range: Inquire
Inquire
- Type: Fluorescence Detector
- Pharmaceutical Application: Inquire
- Wavelength Range: 200 to 600 nm
Inquire
- Type: UV/Visible Detector
- Pharmaceutical Application: Inquire
- Wavelength Range: 190 to 700 nm
- Type: Photodiode Array (PDA) Detector
- Pharmaceutical Application: Inquire
- Wavelength Range: 190 to 800 nm
- Type: Conductivity Detector
- Pharmaceutical Application: Inquire
- Wavelength Range: Inquire
Shimadzu Scientific Instruments
- Type: Inquire
- Pharmaceutical Application: Inquire
- Wavelength Range: 190 to 1000 nm
- Type: Evaporative Light Scattering (ELS) Detector
- Pharmaceutical Application: Inquire
- Wavelength Range: Inquire
- Type: Optical Unit
- Pharmaceutical Application: Inquire
- Wavelength Range: 254 to 280 nm
Inquire
- Type: Refractive Index Detector
- Pharmaceutical Application: Inquire
- Wavelength Range: Inquire
Inquire
Shimadzu Scientific Instruments
- Type: Inquire
- Pharmaceutical Application: Inquire
- Wavelength Range: 200 to 750 nm (depending on model)
Shimadzu Scientific Instruments
- Type: Inquire
- Pharmaceutical Application: Inquire
- Wavelength Range: 190 to 700 nm
- Type: UV-Vis Detector
- Pharmaceutical Application: Inquire
- Wavelength Range: 190 to 700 nm
Inquire
- Type: ELS Detector
- Pharmaceutical Application: Inquire
- Wavelength Range: Inquire
Inquire
- Type: UV-Vis Detector
- Pharmaceutical Application: Inquire
- Wavelength Range: 190 to 700 nm
Inquire
- Type: Evaporative Light Scattering Detector (ELSD)
- Pharmaceutical Application: Inquire
- Wavelength Range: Inquire
Inquire
- Type: Multi-Wavelength Fluorescence Detector
- Pharmaceutical Application: Inquire
- Wavelength Range: 200 to 900 nm
Wyatt Technology Corporation
- Type: Refractive Index Detector
- Pharmaceutical Application: Inquire
- Wavelength Range: 488 to 690 nm
- Type: Mass detector
- Pharmaceutical Application: Inquire
- Wavelength Range: Inquire
Shimadzu Scientific Instruments
- Type: Low Temperature ELSD
- Pharmaceutical Application: Inquire
- Wavelength Range: Inquire
- Type: Isocratic Pumps, Low Volume Degasser with integrated Column oven, Autosampler with zero injection volume
- Pharmaceutical Application: Inquire
- Wavelength Range: 190 to 900 nm
- Type: UV/VIS detector
- Pharmaceutical Application: Photometric determination of light-absorbing substances in the
UV/VIS range.It serves as UV/VIS detector within an ion chromatography
system.
- Wavelength Range: UV range 254 nm, VIS range 550 nm
- Type: Benchtop Fluorometer
- Pharmaceutical Application: Inquire
- Wavelength Range: 250 to 800 nm
Inquire
- Type: Gel Permeation Chromatography (GPC) / Size Exclusion Chromatography (SEC)
- Pharmaceutical Application: Inquire
- Wavelength Range: 190 to 900 nm
- Type: Fraction-Cutting Peak Detector
- Pharmaceutical Application: Inquire
- Wavelength Range: 254 to 280 nm
Inquire
- Type: Microprocessor-controlled Digital Signal Processing (DSP technology)
- Pharmaceutical Application: Its function is to make precise determinations of electroactive substances in the mobile phase of an IC system or of a general liquid chromatography system.
- Wavelength Range: Inquire
- Type: UV/VIS Detector
- Pharmaceutical Application: Photometric determination of light-absorbing substances in the
UV/VIS range. Ideal for chemicals and flammable samples.
- Wavelength Range: UV range 254 nm,
VIS range 550 nm
Select up to 5 products from above to compare or request more information.
Tags:
Please Login or Register to Create Tags