Pharmaceutical Time of Flight Mass Spectrometry

In time-of-flight (TOF) spectroscopy, ions are separated by their mass and are accelerated through an electric field. The velocity of the ions is used to detect the mass-to-charge ratio. Common applications of TOF spectroscopy within pharmaceutical development include metabolite profiling, surface analysis of organic and inorganic molecules, and biomarker discovery. Matrix-assisted laser desorption/ionization (MALDI) TOF spectroscopy is efficient and highly sensitive for analyzing polymeric compounds such as protein and polysaccharides. Purchasing considerations for pharmaceutical TOF equipment include the molecular stability of the compounds to be tested, requirements for instrument size, possible instrument compatibility with quantification software, and the laboratory budget.


CompanyShimadzu Scientific InstrumentsShimadzu Scientific InstrumentsShimadzu Scientific Instruments
ItemAxima Confidence MALDI TOF Mass SpectrometerAxima Assurance MALDI Time of Flight Mass SpectrometerAxima Performance MALDI TOF TOF Mass Spectrometer
Citations
Figures
(3)
Price
Vendor Product PageCompany Product PageCompany Product PageCompany Product Page
DescriptionAn affordable, robust option for routine sample analysis performed manually or automatically, the AXIMA Confidence offers reliable mass information and MS/MS-derived structural detail. A linear mode enables outstanding levels of analysis of high-

An affordable, robust option for laboratories requiring routine manual or automated analysis of a wide variety of sample classes, the AXIMA Assurance provides high-quality, rapid MALDI mass spectra and an array of software tools for data processing

The AXIMA Performance is one of the most powerful tools in mass spectrometry, delivering information-rich spectra with greater sensitivity and higher confidence in identification. Extremely versatile, this MALDI TOF-TOF mass spectrometer utilizes
TypeMALDI-TOF MSMALDI-TOF MSMALDI CID MS/MS (TOF-TOF)
Pharmaceutical ApplicationProteomics experiments, LC MALDI, Polymer analysis, Oligonucleotide/primer analysisProtein profiling, Tissue imaging, Biomarker discover, Single nucleotide polymorphismsProteomics experiments, LC MALDI, Polymer analysis, Oligonucleotide/primer analysis
Sample StateInquireInquireInquire
Resolution5000 FWHM (Linear mode); 15,000 FWHM (Reflectron mode)up to 5000 FWHM5000 FWHM (Linear mode); 20,000 FWHM (Reflectron mode)
Ionization Method(s)MALDIMALDIMALDI
Mass Range1 to 500 kDa (Linear mode) ; 1 to 80 kDa (Reflectron mode)1 to 500 kDa1 to 500 kDa
Scanning SpeedInquireInquireInquire
Regulatory ComplianceInquireInquireInquire
Get quote