High-pressure liquid chromatography systems and instruments cover a wide range of chromatography sciences. This range includes; partition chromatography, normal-phase chromatography, displacement chromatography, reversed-phase chromatography, size-exclusion chromatography, ion-exchange chromatography, bioaffinity chromatography and aqueous normal-phase chromatography.
Get quotes for all products
Select up to 5 products from below to compare or request more information.
Sponsored Products
- Detector(s): Among other things, these can be optionally integrated in the system: Conductivity detection, UV/VIS detection, Amperometric detection
- Flow Rate: 0.001 to 20 mL/min
- Max. Pressure: 0 to 35 MPa
Shimadzu Scientific Instruments
- Detector(s): UV or PDA Detectors, 190 to 800 nm
- Flow Rate: 10 ml/min
- Max. Pressure: Inquire
Shimadzu Scientific Instruments
- Detector(s): Inquire
- Flow Rate: up to 150 mL/min
- Max. Pressure: Inquire
Shimadzu Scientific Instruments
- Detector(s): Inquire
- Flow Rate: 0.0001 – 3.0000 mL/min (1.0 – 105 MPa); 3.0001 – 5.0000 mL/min (1.0 – 80 MPa); 5.0001 – 10.0000 mL/min (1.0 – 22 MPa)
- Max. Pressure: 105 Mpa
- Detector(s): Photodiode Array (PDA), Extended Wavelength PDA (PDA e?), Tunable Ultra-violet (TUV), Evaporative Light Scattering (ELS), Fluorescence (FLR), Single (SQ) / Tandem (TQ) Quadrupole Mass Detectors
- Flow Rate: 0.010 to 2.000 mL/min (in 0.001 mL increments)
- Max. Pressure: 15,000 psi (up to 1 mL/min) or 9000 psi (up to 2 mL/min)
- Detector(s): UV with JASCO X-LC detector
- Flow Rate: 10 ul/min to 10 mL/min
- Max. Pressure: 15,000 Psi
- Detector(s): Options for integration in the system include:
Conductivity detection,UV/VIS detection,Amperometric detection
- Flow Rate: 0.001 to 20 mL/min
- Max. Pressure: 0 to 35 MPa
- Detector(s): Inquire
- Flow Rate: Inquire
- Max. Pressure: Inquire
Sartorius Stedim Biotech GmbH
- Detector(s): Inquire
- Flow Rate: 1 mm cassette: Up to 50 mL/min
3 mm cassette: Up to 100 mL/min
Sartorius Stedim Biotech GmbH
- Detector(s): Inquire
- Flow Rate: 5 to 80 L/h
- Max. Pressure: Inquire
Shimadzu Scientific Instruments
- Detector(s): Inquire
- Flow Rate: Inquire
- Max. Pressure: Inquire
Shimadzu Scientific Instruments
- Detector(s): Inquire
- Flow Rate: 10 to 150 mL/min.
- Max. Pressure: Inquire
Shimadzu Scientific Instruments
- Detector(s): Inquire
- Flow Rate: 0.0001 to 5 mL/min
- Max. Pressure: 66 MPa
Shimadzu Scientific Instruments
- Detector(s): Inquire
- Flow Rate: Inquire
- Max. Pressure: 70 MPa
Shimadzu Scientific Instruments
- Detector(s): Inquire
- Flow Rate: Inquire
- Max. Pressure: 105 MPa
- Detector(s): PDA
- Flow Rate: 0.010 to 4.000 mL/min (in 0.001-mL increments)
- Max. Pressure: 6,000 psi (413 bar), up to 4 mL/min
- Detector(s): Tunable UV Detector, with enhanced chromatographic resolution and maximum-sensitivity detection
- Flow Rate: 0.010 to 2.000 mL/min (in 0.001 mL increments)
- Max. Pressure: 15,000 psi (up to 1 mL/min) or 9000 psi (up to 2 mL/min)
- Detector(s): Ultra-fast electron multiplier and hybrid ADC detector electronics to provide outstanding sensitivity and quantitative performance
- Flow Rate: 0.010 to 2.000 mL/min (in 0.001 mL increments)
- Max. Pressure: 15,000 psi (up to 1 mL/min) or 9000 psi (up to 2 mL/min)
- Detector(s): TUV or TDA Detector
- Flow Rate: 200 nL/min to 100 uL/min
- Max. Pressure: 10,000 psi
- Detector(s): DAD, ELSD
- Flow Rate: 5 to 250 mL/min
- Max. Pressure: 1450 psi
Inquire
- Detector(s): UV-Vis and ELSD
- Flow Rate: 1 to 200 mL/min
- Max. Pressure: 1700 psi
Inquire
- Detector(s): UV-Vis and ELSD
- Flow Rate: 1 to 200 mL/min
- Max. Pressure: 200 psi
Inquire
- Detector(s): UV-Vis, ELSD
- Flow Rate: Up to 500 mL/min
- Max. Pressure: 290 psi
Inquire
- Detector(s): UV-Visible variable wavelength detector
- Flow Rate: 0.001 to 10 mL/min
- Max. Pressure: 40 Mpa
Inquire
- Detector(s): Dual Wavelength, Programmable UV Visible Detector
- Flow Rate: 0.001 to 10 mL/min
- Max. Pressure: 40 Mpa
Inquire
- Detector(s): Dual Wavelength, Programmable UV Visible Detector
- Flow Rate: 0.001 to 10 mL/min
- Max. Pressure: 40 Mpa
Inquire
- Detector(s): Dual Wavelength, Programmable UV Visible Detector
- Flow Rate: 0.001 to 10 mL/min
- Max. Pressure: 40 Mpa
Inquire
- Detector(s): Dual Wavelength, Programmable UV Visible Detector
- Flow Rate: 0.001 to 10 mL/min
- Max. Pressure: 40 Mpa
Inquire
- Detector(s): CE 4700 differential refractive Index Detector
- Flow Rate: 0.001 to 10 mL/min
- Max. Pressure: 40 Mpa
Inquire
- Detector(s): Dual Wavelength, Programmable UV Visible Detector
- Flow Rate: 0.001 to 10 mL/min
- Max. Pressure: 40 Mpa
Inquire